For best performance, it is recommended to mount valve with coil in vertical position or at 45!a angleExtended Solder Type Connections

MKC-1 Coil, Class F Sporlan Catch-All  Filter-Drier is Recommend Upstream.

APPLICATION
Types XSP2, XSP3, and XSP5 are hermetic, direct-acting sole-noid valves primarily for refrigeration and air conditioning applications. These valves may be mounted with coil pointing up or at 45!a angle. Types XSP2, XSP3, and XSP5 series solenoid valves feature extended solder type connections as standard. One important benefit to the user is that all valves in the !°XSP!± series can be installed using either low or no silver content brazing alloy. The MKC-1 coil is Class !°F!± temperature rated and is provide as standard, therefore a high temperature coil is not required for discharge service.

ORDERING INSTRUCTIONS
When ordering complete valves, specify Valve Type, Connections, Voltage and Cycles. When ordering Body Assembly, specify Valve Type and Connections. When order-ing Coil Assembly ONLY, specify Coil Type, Voltage and Cycles. Example: MKC-1 120/50-60. Type XSP Series is identiied by an expanded nomenclature. the system of valve identity is based on port size. In addition, the XSP Series identiies the connection size and type. he advan-tage of the XSP Series nomenclature system is that it allows ease in valve identiication of the standard line and can pro-vide considerable information about special valves supplied to manufacturers. For connections and other special features consult Sporlan Divi-sion of Parker, Washington, MO.

Inches (mm)
D
VALVE E
TYPE A B C Fitting Depth
SERIES Offset
ODF
4.63! 0.55! 2.10! 0.31! 0.30!
XSP2S120
(118 mm) (14 mm) (53 mm) (8 mm) (8 mm)
4.56! 0.49! 2.16! 0.31! 0.24!
XSP2S130
(116 mm) (12 mm) (55 mm) (8 mm) (6 mm)
4.56! 0.49! 2.16! 0.31! 0.24!
XSP3S130
(116 mm) (12 mm) (55 mm) (8 mm) (6 mm)
XSP
5.00! 0.47! 2.19! 0.39!  0.13!
XSP3S140
(127 mm) (12 mm) (56 mm) (10 mm) (3 mm)
4.56! 0.53! 2.19! 0.31! 0.24!
XSP5S130
(116 mm) (13 mm) (56 mm) (8 mm) (6 mm)
5.00!
0.53! 2.19! 0.39! 0.24!
XSP5S140
(127 mm) (13 mm) (56 mm) (10 mm) (6 mm)

CAPACITIES - TONS, CIRCULATION RATE 2
TONS of REFRIGERATION
COIL RATINGS
MOPD
PORT
PRESSURE DROP - psi
VALVE CONNECTION
psi
REFRIGERANT SIZE C
v
TYPE Inches
WATTS
STANDARD
Inches
1 2 3 4 5 7.5 10 15 20
VOLTS/CYCLES
AC AC
XSP2S120 1/4 ODF x 1/4 ODF
0.062! 0.15 300 0.4 0.6 0.7 0.9 1.0 1.2 1.4 1.7 2.0
XSP2S130 3/8 ODF x 3/8 ODF
24/50-60
XSP3S130 3/8 ODF x 3/8 ODF
120/50-60
100.101! 0.30 100 0.8 1.2 1.5 1.7 2.0 2.4 2.8 3.5 4.0
744
208-240/50-60
XSP3S140 1/2 ODF x 1/2 ODF
120-208-240/50-60
XSP5S130 3/8 ODF x 3/8 ODF
0.150! 0.48 50 1.3 1.9 2.4 2.7 3.1 3.8 4.4 5.4 6.3
XSP5S140 1/2 ODF x 1/2 ODF
TONS of REFRIGERATION
COIL RATINGS
MOPD
PORT
PRESSURE DROP - psi
VALVE CONNECTION
psi
REFRIGERANT SIZE C
v
TYPE Inches
WATTS
STANDARD
Inches
1 2 3 4 5 7.5 10 15 20
VOLTS/CYCLES
AC AC
XSP2S120 1/4 ODF x 1/4 ODF
0.062! 0.15 300 0.3 0.5 0.6 0.7 0.8 0.9 1.1 1.4 1.6
XSP2S130 3/8 ODF x 3/8 ODF
24/50-60
XSP3S130 3/8 ODF x 3/8 ODF
120/50-60
100.101! 0.30 100 0.7 1.0 1.2 1.4 1.5 1.9 2.2 2.7 3.2
744
208-240/50-60
XSP3S140 1/2 ODF x 1/2 ODF
120-208-240/50-60
XSP5S130 3/8 ODF x 3/8 ODF
0.150! 0.48 50 1.1 1.5 1.9 2.2 2.4 3.0 3.5 4.3 5.0
XSP5S140 1/2 ODF x 1/2 ODF
CAPACITIES - kW, CIRCULATION RATE 2
kW of REFRIGERATION
COIL RATINGS
MOPD
PORT
PRESSURE DROP - bar
VALVE CONNECTION
bar
REFRIGERANT SIZE K
v
TYPE Inches
WATTS
STANDARD
mm
0.07 0.14 0.21 0.27 0.34 0.52 0.69 1.03 1.37
VOLTS/CYCLES
AC AC
XSP2S120 1/4 ODF x 1/4 ODF
2 mm 0.13 20.6 1.4 1.9 2.5 3.0 3.3 4.2 4.9 6.0 7.0
XSP2S130 3/8 ODF x 3/8 ODF
24/50-60
XSP3S130 3/8 ODF x 3/8 ODF
120/50-60
103 mm 0.25 6.9 2.8 4.2 5.1 6.0 6.9 8.4 9.8 12.1 14.1
744
208-240/50-60
XSP3S140 1/2 ODF x 1/2 ODF
120-208-240/50-60
XSP5S130 3/8 ODF x 3/8 ODF
4 mm 0.41 3.4 4.6 6.7 8.3 9.5 10.7 13.2 15.3 19.0 22.0
XSP5S140 1/2 ODF x 1/2 ODF
kW of REFRIGERATION
COIL RATINGS
MOPD
PORT
PRESSURE DROP - bar
VALVE CONNECTION
bar
REFRIGERANT SIZE K
v
TYPE Inches
WATTS
STANDARD
mm
0.07 0.14 0.21 0.27 0.34 0.52 0.69 1.03 1.37
VOLTS/CYCLES
AC AC
XSP2S120 1/4 ODF x 1/4 ODF
2 mm 0.13 20.6 1.1 1.6 1.9 2.3 2.6 3.2 3.9 4.7 5.6
XSP2S130 3/8 ODF x 3/8 ODF
24/50-60
XSP3S130 3/8 ODF x 3/8 ODF
120/50-60
103 mm 0.25 6.9 2.3 3.3 4.0 4.7 5.3 6.7 7.7 9.5 11.1
744
208-240/50-60
XSP3S140 1/2 ODF x 1/2 ODF
120-208-240/50-60
XSP5S130 3/8 ODF x 3/8 ODF
4 mm 0.41 3.4 3.7 5.3 6.5 7.6 8.4 10.4 12.1 14.9 17.4
XSP5S140 1/2 ODF x 1/2 ODF

 