actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

MAC proportional pressure control PQE and pressure control system SeriesPPC92B

OPERATIONALBENEFITS
1. Reliable operation, using two MAC 92 Series
with balanced pilot.
2. Fast response.
3. Long life.
4. High flow.
5. Low power consumption.
6. Not affected by vibrations.
7. Accuracy : 2.5 % full scale
8. Analog command signal and output.

GENERALDATA
Ambient temperature :32 to 120F/0 to 50
LED indicators :Red : power on - Green : pressure achieved
Enclosure :Aluminium Barstock, sealed
Vibration :Not affected
Port size :3/8± (side only
Connector :3, 5, 6 or 7 Pin Plug-in or 7 wire grommet
Mounting :Any plane
Washdown :Standard

ELECTRICALDATA
Supply voltage :20.4 to 26.4 VDC
Supply current :50 to 350mA
Command signal :0 to 10V or 4 to 20mA
Command type :Single-ended or differential
Input impedance :4.99 k 1.0% (voltage316  0.1% (currentAnalog Monitor Signal (AMS) :0 to 10 Volt
Logic Monitor Signal (LMS) :2 types of signals (see How to order) (sinking)
EMI/RFI protection :Common mode and high frequency noise reduction for electrical inputs

PNEUMATICDATA
Inlet pressure* :120 PSI max (for 10-100 PSI output pres.),8 BAR max (for 0.66-6.6 BAR output pres.)
Fluids :Compressed air or inert gases
Lubrication :Not required. However, if used, a medium aniline point oil is recommended
Output pressure :0 to 10, 30, 45, 60, 100 PSI, 0 to 0.66, 2, 3, 4, 6.6 BAR
Overall accuracy :2.5% full scal
Flow :Cv 2.0/2000 Nl/min3
Minimum closed end volume :80.0 cubic inch - 1310 cm
* 20 PSI maximum inlet for 10 PSI output pressure - 1.3 BAR maximum inlet for 0.66 BAR output pressure

Write a review

Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below:



Export Company Export Company Export Company Global Trade Leads - Import & Export on our award-winning International Trade Site